Quadra Chek 200 User Manual
ND 1203 QUADRA-CHEK ND 1200 SKU: ND 1203 QUADRA-CHEK ND 1200 Operating temperature: 0 °C to 45 °C: Protection IEC 60529: IP 00, front panel IP 40: Electrical connection: 1 m with M23 coupling: Application: Digital Readout for Tool Presetters: Axes: 3 (XYQ) or 3 (XYZ) Encoder inputs: TTL: Display step. QUADRA-CHEK 2000 Evaluation Electronics for Metrology Applications. 200 169 18.75 130 170 51 M5 X X A 2:1 A Product Information QUADRA-CHEK 20 Mounting the QUADRA-CHEK 2000. The User’s Manuals are based on this part. It can be reordered if a replacement is necessary.
Collecting Data from a Quadra-Chek 2000
Windmill software lets you continually log data from a Quadra-Chek 2000, and other instruments with an RS232 serial port, on a PC running Windows. All data is time-stamped and can be imported into Excel either during or after data collection. Alternatively, subscribers to the Monitor newsletter (ISSN 1472-0221) can download free logging software: ComDebug. This lets you log data from one instrument and save it in a text file. After collection is finished data can be imported into Excel.
ComDebug Settings for a Quadra-Chek 2000
Read this in conjunction with the Getting started with ComDebug and COMIML Serial Driver page.
For information on what each of the settings means, see the Serial Driver Settings Overview.
COM Port Settings
These should match those actually in use by your Quadra-Chek 2000. The default settings are given below. Make sure that the Quadra-Chek is set up to talk to the Computer (Xon/Xoff) and not a printer (Hardware). To do this, on the Quadra-Chek: Press the 5 key (setup), scroll down until RS232 appears and press Enter. Scroll down until Protocol appears and make sure Xon/Xoff is selected.
Comm Port: | Select the port to which your instrument is connected. |
Baud Rate: | 4800 |
Data Bits: | 8 |
Parity: | None |
Stop Bits: | 2 |
Flow Control: | XonXoff |
Data Format
Data format: | ASCII | |
Prompt Command: | Use an ASCII string representing a front panel key, followed by a carriage return (use the NonPrint menu to enter this). For example, PRINT<CR> or X<CR> | |
Example data string: | X -1234.567 mm <CR> Where <CR> is a carriage return character (013). | |
Example parsing: | Search: X Ignore Until: -.0123456789 Extract Until: <space> where <space> is a space character (press the space bar, don't type<space>). This would capture the X co-ordinate. To capture the Y co-ordinate: Search: Y Ignore Until: -.0123456789 Extract Until: <space> |
Instrument Timing
Read: | In the Background |
Timeout: | 1000 ms |
Instrument Idle or Wait Time: | 500 ms |
Data Persistence Time: | 1000 ms |
Trouble-Shooting
- Press the Print button on the Quadra-Chek: you should see data from it appear in ComDebug. If not you may have a cabling or communication problem.
- try connecting the fluorometer to alternative COM ports
- If using a USB-RS232 converter, its settings must also match those used by the Quadra-Chek, see our USB-Serial converter page for help, especially point 7.
- Check your cable, if possible try swapping the cable for another.
- If still nothing see our Trouble-Shooting Serial Port Connections page.
- If, on pressing Print on the Quadra-Chek, nonsensical data is received in ComDebug, you may have the Quadra-Chek set up to talk to a printer rather than a computer. Use the Setup up and down arrow keys to change the RS232 protocol to Xon/Xoff.
Further Information:
Quadra-Chek 2000 Operation Manual
Windmimll results in 90% efficiency improvement for a company using a Quadra-Chek 2000 optical measuring system
Getting Started with ComDebug and COMIML
Technical SupportCOM Port Settings
QUADRA-CHEK 3014 NC | QUADRA-CHEK 3024 NC | |
Axes | 4 (XYZQ), two of which can be enabled with a software option | |
Encoder interface Input frequency | 1 VPP, 11 µAPP, EnDat 2.2 1 VPP: ≤ 400 kHz; 11 µAPP: 150 kHz | TTL ≤ 5 MHz |
Subdivision factor | 4096-fold (only with 1 VPP) | |
Display step | Adjustable, max. 8 digits Linear axes XYZ: to 0.00001 mm; angular axis Q: to 0.00001° (00° 00’ 00.1”) | |
Display | 12.1-inch multi-touch screen (16:10); resolution: WXGA 1280 x 800 pixels, for position values, dialogs, inputs, graphics functions, and video display (VED software option) | |
Functions |
| |
Encoder input For Apple phones, no additional software is required (just point the camera at the QR code and follow the instructions). You need to scan the QR code shown on the site using your mobile phone (or tablet) and perform the required actions on your device.In order to be able to scan the code, use the camera of your phone. Hp12c classic simulator 4.2 serial download. | One additional encoder input (software option AEI1) | |
Edge detection | Video (software option VED):
Optically (software option OED):
| |
Assisted focus | Assisted focusing of the camera on the object of measurement (software option AF) | |
3-D measuring applications | Measured-value acquisition via touch probe (software option 3D) | |
Error compensation |
| |
Data interface | 1x Ethernet 100 MB/1 Gbit (RJ45); 3x USB 2.0 Hi-Speed (Type A) | |
Other connections |
| |
Accessories | Multi-Pos and Duo-Pos stand, Multi-Pos holder, power cable, measuring standard, 2-D demo part, adapter connector | |
Power connector | AC 100 V to 240 V (±10 %), 50 Hz to 60 Hz (±5 %), ≤ 79 W | |
Operating temperature | 0 °C to +45 °C (storage temperature: –20 °C to +70 °C) | |
Protection EN 60529 | IP65; back panel: IP40 | |
Mounting | Multi-Pos or Duo-Pos stand, Multi-Pos holder, fastening systems compatible to VESA MIS-D 100 | |
Mass | Unit: 3.5 kg; unit with Multi-Pos holder: 4.1 kg; Unit with Duo-Pos stand: 3.8 kg; unit with Multi-Pos stand: 4.5 kg | |
1) Supported camera manufacturer: IDS Imaging Development Systems GmbH; |